Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Braz. dent. sci ; 25(4): 1-6, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1400990

ABSTRACT

Objective: The current study aimed at assessing the induced apical pressure at various simulated irrigant flow rates. Materials and Methods: Forty eight freshly extracted single-rooted premolars were decoronated and prepared to size 30 0.04 taper using HY-Flex CM rotary file system and were scanned using cone-beam computed tomography (CBCT). The scanned images were reconstructed to three-dimensional Computer-aided design models (CAD) and the 3D needle was also reconstructed. Finally, simulations were done by placing the 30 gauge open-ended needle 3 mm short of the working length. Results: There was a statistically significant difference (p<0.05) among the different groups compared. 1 ml/min flow rate induced the least apical pressures (p<0.05) as compared to the other types. Conclusion: 1 ml/min flow rates induced the least apical pressures when open-ended needles are used for irrigation.(AU)


Objetivo: O presente estudo teve como objetivo avaliar a indução de pressão apical em várias taxas de fluxo irrigante simuladas. Material e Métodos: Quarenta e oito raízes de pré-molares unirradiculares recém extraídos tiveram suas coroas removidas, foram preparados para uma conicidade de tamanho 30 0.04 através de um sistema rotatório de limas HYFlex CM e foram escaneados via tomografia computadorizada cone-beam (CBCT). As imagens escaneadas e as agulhas para irrigação foram reconstruídas em modelos tridimensionais de design assistido por computador (CAD). Ao final, foram feitas simulações através de agulhas de calibre 30 e 3 mm a menos que o comprimento de trabalho. Resultados: Houve diferença estatisticamente significativa (p<0.05) entre os diferentes grupos. A taxa de fluxo de 1 ml/min induziu as menores pressões apicais (p<0.05) quando comparada às demais taxas. Conclusão: Taxas de fluxo de 1 ml/min induziram as menores pressões apicais quando agulhas de ponta aberta foram utilizadas para irrigação (AU)


Subject(s)
Pressure , Bicuspid , Tomography, X-Ray Computed , Dental Pulp Cavity
2.
Chinese Journal of Traumatology ; (6): 261-269, 2019.
Article in English | WPRIM | ID: wpr-771592

ABSTRACT

PURPOSE@#The fractures of anterior mandible are subject to severe torsional forces due to muscles acting in opposite directions. 3D miniplate has been suggested as a good alternative by some researchers. However, finite element model (FEM) studies indicate that labio-inferior positioning of two miniplates perpendicular to each other offers better stability as compared to labial positioning. This study aims at combining the advantages of a single 3D miniplate and labio-inferior positioning of two conventional miniplates, which was assessed by finite element analysis along with a pilot clinical trial.@*METHODS@#Two FEM models were created using CT data of a 24-year-old patient with Angle class I occlusion: control model with labial plating and study model with labio-inferior plating. The models were processed with MIMICS® (materialise, Leuven, Belgium), CATIA® (Dassault Systemes) and finite element analysis softwares. Parameters adopted for analysis were (1) displacement (mm) of fracture fragments during each screw fixation, (2) lingual splay and post fixation stability of fracture fragments with masticatory load, and (3) stress distribution (MPa) across fracture fragments. Moreover, a pilot clinical trial including five patients with anterior mandible fracture was conducted. The fractures were managed by intraoral open reduction and 3D miniplate fixation in labio-inferior position. Intraoperative interfragmentary gap, post fixation lingual splay and radiographic fracture union and complications were assessed clinically.@*RESULTS@#Labio-inferior plating demonstrated less displacement (mm) of fracture fragments during screw fixation (0.059 vs. 0.079) as well as after application of masticatory load (1.805 vs. 1.860). Negligible lingual splay and less stress distribution (MPa) across fracture fragments (1.860 vs. 1.847) were appreciated in the study group as compared to control group. Clinical trial support the favorable outcome related to intraoperative and postoperative assessment parameters.@*CONCLUSION@#FEM analysis and clinical trial reveal better results with labio-inferior positioning of 3D miniplate when compared to labial positioning.

3.
Article in English | IMSEAR | ID: sea-174159

ABSTRACT

Probiotics may be defined as the ‘Live microorganisms which when administered in adequate amounts confer a health benefit on the host’. Probiotics are being utilized to check the growth of caries promoting and periodontal pathogens in the oral cavity. This article describes the application of lactobacilli probiotics in oral health care and pedodontic practice.

SELECTION OF CITATIONS
SEARCH DETAIL